Basics Using Multitester


Basics Using Multitester

0 = lever bookmark / Feature measurement
1 = point 0 to 1 to measure DC voltage below 20v
2 = point 0 to 2 to measure DC voltage below 200V
3 = 0 3rd point to measure DC voltage under 500v
4 = point 0 to 4 if not used for off / save battery multitester.
5 = point 0 to 5 For measuring the flow below 500V AC
6 = point 0 to 6 measuring flow below 200V AC
7 = measuring ohms / resistance / capacitance
8 = point 0 to 8 for the buzzer (if the buzzer sounds sign or connected)
note: BUZZER value 000 total short omen.
buzer can be done to see the value of Diodes.
9 = point 0 to 9 for temprature sensor using the sensor cable

https://scontent-sin1-1.xx.fbcdn.net/hphotos-xpf1/v/t1.0-9/10530702_811044965610127_1510030914107673448_n.jpg?oh=38bf6fbc796c9bac5e8ce4363e8af545&oe=568744D3
Note For probe Com = black hole
for details please consult the functions below ...

How to Use a Volt Meter Digital multitester.

Attach the black wire to COM (Ground) and plug the red cord to the V
Determine the measurement object, for example, will measure the capacity of the laptop charger adapter 16V.
Look at the scale on Multitester V (Volt) is twofold:

Volt DC - (Voltage unidirectional): Battery Voltage, Output Voltage IC Power, etc. (There is polarity + and -).
AC Volt ~ (Voltage Alternating Behind): Voltage PLN, and the like.

Commonly used in the measurement of weak currents such as the measurement of cell phones, etc. have been the DC Volt -.
Once selected scale DC Volt, no values listed in the DC part of the Volt. Examples are as follows: 200mV means will measure the maximum voltage of 0.2 Volts

- 2V means will measure the maximum voltage 2 Volts
- Will measure the voltage of 20V means that maximal 20 Vollt
- 200V means will measure the maximum voltage 200V
- 500V means will measure the maximum voltage 500V

Use the appropriate scale for the measurement, eg 16 Volt adapter laptop charger use on 20V scale. The results will be accurate for example read: 14.86 Volt.

After the measurement object already exists, and the right scale is selected, then do the measurements by attaching the red wire to the positive power jack and the black wire to the negative power jack. Measurement results will appear.
If the cable is reversed the result will still appear, but there is a negative sign in front of the result. Differences with Analog multitester. If the cable needle would be stuck upside left.

NB: * if the result wanted to freeze and in the recorded result, press the "HOLD".
If the screen is less bright display systems, press the "sun"

At PLN voltage measurements, the scale was moved to the AC Volts (~) and then scale it to 500 V.

Plug the red and black wires to the respective receptacle (alternating allowed). But be careful fear no wires are chipped, can be electrocuted.
The results will appear for example: 216 means that the PLN voltage of 216 Volts.
If using a scale of 200, then the result will be one sign over load alias exceeds the scale of 200 Volts.